日韩免费高清丨高h av丨黄床大片免费30分钟国产精品丨中文字幕丰满乱子伦无码专区丨性色av免费丨亚洲欧美丝袜 动漫专区丨精品国精品国产自在久不卡丨妺妺窝人体色www在线下载丨久久国产福利国产秒拍丨亚洲视频观看丨久久久久久a亚洲欧洲av丨色啪综合丨好屌草这里只有精品丨丁香婷婷久久丨波多野吉衣久久丨欧美精品久久丨亚洲乱码日产精品一二三丨久久综合给久久狠狠97色丨青青草国产在线视频丨成人日批丨xxxxx欧美妇科医生检查丨久久国产欧美日韩精品丨日本久久99丨精品国产乱码久久久久久夜甘婷婷丨超碰成人97

021-33882916

色譜附件


  • 產(chǎn)品圖
  • 訂貨信息
  • 產(chǎn)品描述
  • E360BY08
    Silica Emitter, 8 μm Orifice. 360 μm OD x 20 μm ID x 5 cm L.
  • E360BY15
    Silica Emitter, 15 μm Orifice. 360 μm OD x 20 μm ID x 5 cm L.
  • E360BY30
    Silica Emitter, 30 μm Orifice. 360 μm OD x 20 μm ID x 5 cm L.
  • E360BZ08
    Silica Emitter, 8 μm Orifice. 360 μm OD x 10 μm ID x 5 cm L.
  • E360BZ15
    Silica Emitter, 15 μm Orifice. 360 μm OD x 10 μm ID x 5 cm L.
  • E360BZ30
    Silica Emitter, 30 μm Orifice. 360 μm OD x 10 μm ID x 5 cm L.
  • All pulled ESI emitters are made of quartz silica. For optimum performance, the inner surface is rinsed with acidified water, but you will need to condition it for your set-up. This will happen automatically in the first two runs of your nLC workflow. When you install a new emitter, we recommend you to pass two standard runs before analyzing your samples.

    The Emitter surface finish is polished and rinsed with acidified water (HPLC grade). Under the influence of the electric field, the liquid wets the glass and the meniscus is anchored at the outer edge of the tip. The typical voltages required to stabilize the emitters is 1.5kV to 2.5kV, smaller orifice requires lower voltage.


  • F360MV08
    Empty emitter fused silica column, 8 μm Tip Orifice. 360 um OD × 75 um ID × 20 cm L.
  • F360KV08
    Empty emitter fused silica column, 8 μm Tip Orifice. 360 um OD × 75 um ID × 60 cm L.
  • F360MV15
    Empty emitter fused silica column, 15 μm Tip Orifice. 360 um OD × 75 um ID × 20 cm L.
  • F360KV15
    Empty emitter fused silica column, 15 μm Tip Orifice. 360 um OD × 75 um ID × 60 cm L.
  • F360MV08F
    Empty fritted emitter fused silica column, 8 μm Tip Orifice. 360 um OD × 75 um ID × 20 cm L.
  • F360KV08F
    Empty fritted emitter fused silica column, 8 μm Tip Orifice. 360 um OD × 75 um ID × 60 cm L.
  • F360MV15F
    Empty fritted emitter fused silica column, 15 μm Tip Orifice. 360 um OD × 75 um ID × 20 cm L.
  • F360KV15F
    Empty fritted emitter fused silica column, 15 μm Tip Orifice. 360 um OD × 75 um ID × 60 cm L.
  • Fresh Bioscience Ltd. offers two types of integrated emitter fused silica capillary tubing, fritted and non-fritted. All tubing are designed for user to self pack their own nanoLC columns with high performance and reproducibility. Normally we recommend fritted integrated emitter fused silica capillary tubing for peptides mapping, it drives the highest proteomics performance available. A consistent results over multiple experiments and hundreds of injections, which always make you be happy.